English Afrikaans Albanian Arabic Armenian Azerbaijani Basque Belarusian Bulgarian Catalan Chinese (Simplified) Chinese (Traditional) Croatian Czech Danish Dutch Estonian Filipino Finnish French Galician Georgian German Greek Haitian Creole Hebrew Hindi Hungarian Icelandic Indonesian Irish Italian Japanese Korean Latvian Lithuanian Macedonian Malay Maltese Norwegian Persian Polish Portuguese Romanian Russian Serbian Slovak Slovenian Spanish Swahili Swedish Thai Turkish Ukrainian Urdu Vietnamese Welsh Yiddish
Translate

traquelogo

The Anville Series 825 TVI (Thermal Validation Interface) is designed for use with EaziVal SE software. Anville's thermal validation systems can be used wherever it is necessary to maintain a formal record to prove that the correct temperatures and pressures have been achieved during a critical process.

The Anville Series 825 TVI differs from the majority of data loggers by the design of the thermocouple input connection, associated thermocouple cold junction compensation and in the use of analogue input parallel processing enabling the unit to have an acquisition rate of better than once per second for all inputs. The Series 825 TVU uses individual high-speed amplification and analogue to digital conversion on each input channel with conversion to engineering units (°C/°F) carried out by the internal microcontroller. Data is communicated to the computer in the correct engineering units enabling the system to have a traceable calibration certificate. The Series 825 TVI has an internal power supply to provide a 20VDC excitation voltage for the 4-20mA inputs and no separate power supply is required for a loop powered transducer.

In the Anville Series 825 TVI all cold junction compensation errors are minimised by using correctly compensated miniature type T thermocouple connectors with matching class 1 thermocouple wiring to the internal cold junction sensor. A 1/3 DIN PT100 sensor measures the cold junction temperature to an accuracy of ±0.1°C at 0°C. Design of the physical layout of the cold junction reduces any thermal scatter to a typical deviation of ±0.05°C.

The Anville Series 825 measurement range for type T thermocouples is -200°C to 300°C with a resolution of 0.01°C. Over a measurement range from -50°C to 300°C the overall system accuracy is ±0.25°C. This accuracy is maintained over an ambient operating temperature range from 0°C to 50°C and includes all errors due to thermocouple cold junction compensation, DC amplification, A/D conversion and thermocouple linearisation.

The Series 825 TVI accuracy of ±0.25°C is the worst case "out of the box" value including all system errors but excluding thermocouple sensor error.

Series 825 TVI Specifications

  • Type T Thermocouple inputs Channels 1-16
  • 4-20mA Channels PR1 & PR2
  • Type T thermocouple input Measurement range: -50.0°C to 300.0°C; Accuracy: +/- 0.25°C; Resolution: 0.01°C
  • Type T thermocouple input -50.0°C to 300.0°C: -200.0°C to -50.0°C; +/- 0.25°C: +/- 1.0°C; 0.01°C: 0.01°C
  • Transducer input -200.0°C to -50.0°C: 4-20mA; +/- 1.0°C: +/- 0.1%; 0.01°C: 1µA
  • Scanning speed All channels in less than 1 sec
  • Transducer power supply (internal) 20VDC
  • Operating ambient temperature 0°C to 50°C
  • Dimensions W x H x D 240mm x 140mm x 290mm
  • Weight  4kg

If you would like more information, please contact us to "Get On TRAQuE"

Anville Series 825 TVI
SKU Anville_825_Datalogger
Brand Anville Instruments

Office Address

OfficeLocation

Our contact details in Singapore are:

TRAQuE Pte. Ltd.
51 Bukit Batok Crescent,
#08-25 Unity Centre
658077
Singapore
+65 6316 3885
+65 9735 1384
+65 6316 3885
www.traqueasia.com
traque-pte-ltd

Our mailing address in Malaysia is:

TRAQuE Sdn. Bhd.
Suite 13-10, Level 13,
Johor Bahru City Square Office Tower,
106 - 108, Jalan Wong Ah Fook,
80000 Johor Bahru.

If you would like further information on our products or services, then feel free to contact us using the form below. We look forward to working with you.

Slider

Contact Us
Please contact us if you would like further information on any of our products or services. We will get back to you as soon as possible.
Your Company Name
Please enter your name!
Please enter your email!
First Line of Your Address
Second Line of Your Address
Phone Number (inc Std Code)...
Write your message!

Latest News

TRAQuE Awarded bizSAFE Star

TRAQuE is pleased to announce we have been awarded BizSafe Star by the WSH Council.

 

Congratulations to the team and well done in the continued efforts in supporting safety.

 

TRAQuE Malaysia

We’ve always placed great importance on being close to our customers. The ability to provide local resources, respond quickly and be onsite as required has proven extremely valuable in the seven years since we began operations in Asia.

 

Protak Scientific Partnership
Protak Scientific Logo

We're delighted to be kicking off our partnership with Protak Scientific in Singapore. This revolutionary alternative to biological indicators for use when assessing VHP effectiveness is significantly quicker than current methods and can provide linear quantitative data, resulting in optimised cleaning processes and increased productivity.

We use cookies to personalise content, to provide social media features and to analyse our traffic. We may also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. You consent to our cookies if you continue to use our website.
Ok