Multiple use logger for Medical shipment use. The Medical data loggers are fitted with long-life Lithium Thionyl Chloride (3.6V) batteries with a wide operating temperature range, allowing low-temperature recordings down to –50°C(-58°F).
Accuracy & Traceability –Calibrated to 0.2°C / 0.35°F
The Medical data loggers go through a 3-Point calibration and correction process during manufacturing. The corrections are then applied to each data logger. Traceable Calibration Certificates are included with each logger from our ISO/IEC 17025 accredited laboratory. PDF copies of Calibrated Certificates are also available.
32K Non-volatile Memory
The medical Advanced Multi-Use data logger supports 32K of memory (32,511 samples). User-configurable sample periods provides from 16 hours up to 2 years of data recording.
Multi-Use Recorders
Use the Econolog recorder time and time again. After each use, download your data and the recorder is ready for its next application.
LED Status Indicators The entire Temprecord recorder range has out of range indication. Set parameters and a red or green LED flash every 10 seconds will tell the user at a glance whether or not data recording has remained within the limits set. | Push Button Start / Stop | Retaining Hole Fully molded and ultrasonically welded retaining hole for easy securing of the data logger within different environments |
If you would like more information, please contact us to "Get On TRAQuE"
ISO 17025 Calibration |
Medical |
32K Non-volatile |
32,511 samples |
Programmable between 2 second and 36 hours in 2 second increment |
10s to 36 hrs |
Logger Button (if enabled), Palm PDA/Reader, TRW Software/Reader |
16hrs up to 2 years |
-50 ̊C to +60 ̊C (-58 ̊F to +140 ̊F) |
With Probe: -50 ̊C to +60 ̊C (-58 ̊F to +140 ̊F) |
With Probe: 0.2 ̊C over the range -40 ̊C to +50 ̊C (0.35 ̊F from -40 ̊F to +122 ̊F) else 0.5 ̊C (0.9 ̊F) |
0.2 ̊C (0.35 ̊F) over the range -20 ̊C to +50 ̊C (-4 ̊F to +122 ̊F) else 0.5 ̊C (0.9 ̊F) |
0.01 ̊C (0.01 ̊F) |
One flash from Green LED Indicator every 10 seconds |
One flash from Red LED Indicator every 10 seconds |
Lithium Thionyl Chloride (3.6V) |
Blue |
IP67 or NEMA 6. Fully welded FDA approved food grade casing |
2 years on data logger from date of purchase 2 years on battery |
Dimension (L x W x H) | 0 x 0 x 0 |
Weight | 0 |
Our contact details in Singapore are: TRAQuE Pte. Ltd.51 Bukit Batok Crescent, #08-25 Unity Centre 658077 Singapore | |
+65 6316 3885 | |
+65 6316 3885 | |
www.traqueasia.com | |
traque-pte-ltd |
Our mailing address in Malaysia is:
TRAQuE Sdn. Bhd. Suite 13-10, Level 13, Johor Bahru City Square Office Tower, 106 - 108, Jalan Wong Ah Fook, 80000 Johor Bahru. |
If you would like further information on our products or services, then feel free to contact us using the form below. We look forward to working with you.
TRAQuE is pleased to announce we have been awarded BizSafe Star by the WSH Council.
Congratulations to the team and well done in the continued efforts in supporting safety.
We’ve always placed great importance on being close to our customers. The ability to provide local resources, respond quickly and be onsite as required has proven extremely valuable in the seven years since we began operations in Asia.
We're delighted to be kicking off our partnership with Protak Scientific in Singapore. This revolutionary alternative to biological indicators for use when assessing VHP effectiveness is significantly quicker than current methods and can provide linear quantitative data, resulting in optimised cleaning processes and increased productivity.